Contact Details
  • Dolly@ysycom.com
  • +86 13862584819
  • Room1814, Building1, Xiangti Business Plaza, Suzhou High-tech District ,China 215009
Auxiliary equipment Closed Cooling Tower

Closed cooling tower is full-closed, it will not appear the phenomenon such as the dust into the cooling pipe and control system to lead the pipeline blockage.

Closed cooling tower adopts soft water circulating system, it is not easy to form the incrustation to lead the pipeline overheating. It adopts automatic digital control system, there’re other features, such as: energy saving, environmental protection, high efficiency, high accuracy and easy to use. Full-confined space, the cooling medium is not affected by the outside environment, and the environment will not be polluted.

Contact us

Auxiliary equipment Closed Cooling Tower

A closed cooling tower is fully closed; it will not exhibit phenomena such as the dust into the cooling pipe and the control system due to pipeline blockage.

Closed cooling tower adopts a soft water circulating system, making it difficult to form incrustation on the pipeline overheating. It adopts an automatic digital control system; there are other features, such as energy saving, environmental protection, high efficiency, high accuracy, and easy use. Full-confined space, the cooling medium is not affected by the outside environment, and the environment will not be polluted.

It can cool brine, oil, alcohol, quenching, and chemical liquids and other mediums; the composition will not be affected by the medium, resulting in no loss and no leakage. Closed cooling tower adopts the type which is air cooling, evaporation heat, double cooling, and the cooling efficiency is higher and energy saving. The type is prying, so the installation of the pipeline is simple and convenient. You don't need to dig the reservoir; it can save water and protect the environment.


ModelCooling capacityMotor powerFan deliverySpray pumpPipe diameter of device interface
FlowHeat extractionWater pump powerWater inlet/outletOverflowSewage draining exitWater replenishing
power
m³/hKWKWm³/hKWmmmmmmmm
30D301741.5*2384000.75DN80DN25DN25DN25
40D402321.5*2512001.1DN100DN32DN32DN32
50D502901.5*2640001.5DN100DN32DN32DN32
65D653782.2*2832001.5DN100DN32DN32DN32
80D804653*21024002.2DN125DN40DN40DN40
100D1005814*21280003DN125DN40DN40DN40
125D1257275.5*21600003DN150DN40DN40DN40
150D1508724*31920004DN150DN40DN40DN40
180D18010465.5*32400004DN125*2DN40DN40DN40
200D20011634 *42560004DN125*2DN40DN40DN40
225D22513084 *42560005.5DN150*2DN40DN40DN40
250D25014535*43200005.5DN150*2DN40DN40DN40